Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | CHX |
Model Number : | CHX-DM022 |
Certification : | CE, RoHS |
Price : | Negotiation |
Payment Terms : | T/T, Western Union,Paypal,L/C |
Supply Ability : | 50000pcs/month |
Delivery Time : | 5-35days |
40 ~ 1000Hz True RMS Infrared Themometer With GB / T13978-92 Digital Multimeter
Security Information
Instrument in line with GB / T 13978-92 digital multimeter general
technical conditions, in line with GB4793.1-1995 (IEC-61010-1,
IEC-61010-2-032) electronic measuring instruments safety
requirements, is a secondary pollution, For CAT IV 600V and CAT III
1000V.
Follow the safe operating instructions to ensure safe use of the
instrument.
Appropriate use and protection, the instrument will give you a
satisfactory service.
3.2.3 AC voltage
Range | Resolution | Accuracy |
6V | 0.001V | ±(0.8% of reading + 3words) |
60V | 0.01V | |
600V | 0.1V | ±(1.0% of reading + 10words) |
- Input impedance: 10MΩ
- Maximum input voltage: 600V AC (RMS) or 600V DC
- Frequency range: 40 ~ 1000Hz True RMS
Note:
In the small voltage range, the pen is not connected to the circuit
under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high
sensitivity, does not affect the actual measurement results.
3.2.4 Alternating current
Range | Resolution | Accuracy |
600.0uA | 0.1uA | ±(1.5% of reading +10words) |
6000uA | 1uA | |
60.00mA | 0.01mA | |
600.0mA | 0.1mA | |
6A | 0.001A | ±(2.5% of reading +10words) |
10A | 0.01A |
- Overload protection: mA range fuse (self-recovery fuse 200mA /
250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous
measurement time is not longer than 15 seconds, after the
measurement to stop the current measurement for more than 1 minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.
3.2.5 DC
Range | Resolution | Accuracy |
600.0uA | 0.1uA | ±(1.0% of reading +5words) |
6000uA | 1uA | |
60.00mA | 0.01mA | |
600.0mA | 0.1mA | |
6A | 0.001A | ±(2.0% of reading +10words) |
10A | 0.01A |
- Overload protection: mA range fuse (self-recovery fuse 200mA /
250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous
measurement time is not longer than 15 seconds, after the
measurement to stop the current measurement for more than 1 minute.
3.2.6 Frequency
Range | Resolution | Accuracy |
9.999Hz | 0.001Hz | ±(1.0% of reading +3words) |
99.99Hz | 0.01Hz | |
999.9Hz | 0.1Hz | |
9.999kHz | 0.001kHz | |
99.99KHZ | 0.01kHZ | |
999.9KHZ | 0.1KHZ | |
9.999MHZ | 0.001MHZ |
- Overload protection: 250V DC or AC (rms)
- Input voltage range: 600mV ~ 10V AC (with the measured frequency
increases, the input voltage should also increase)
3.2.7 Duty cycle
Range | Resolution | Accuracy |
0.1 – 99.9% | 0.1% | ± 3.0% |
- Frequency response: 10 ~ 10MHz
- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)
- Maximum input voltage: 250V AC (rms)
Resistance
Range | Resolution | Accuracy |
600W | 0.1W | ±(0.8% of reading +3words) |
6kW | 0.001kW | |
60kW | 0.01kW | |
600kW | 0.1kW | |
6MW | 0.001MW | ±(1.2% of reading +3words) |
60MW | 0.01MW |
- Open circuit voltage: approx. 1.0V
- Overload protection: 250V DC or AC (rms)
Transistor test
Range | Description | Test Conditions |
hFE | The display reads the approximate value of hFE(0~1000) | Base current of about 10uA; Vce about 2.8V |
Capacitance
Range | Resolution | Accuracy |
9.999nF | 0.001nF | ±(4.0% of reading +3words) |
99.99nF | 0.01nF | |
999.9nF | 0.1nF | |
9.999mF | 0.001mF | |
99.99mF | 0.01mF | |
999.9mF | 0.1mF | |
9.999mF | 0.001mF | ±(5.0% of reading +3words) |
99.99mF | 0.01mF | Not calibrated |
- Overload protection: 250V DC or AC (rms)
Temperature test
Range | Accuracy | Resolution |
-20℃-300℃ | ±(1.0%+4d) | 1℃ |
301℃-1000℃ | ±(1.9%+5d) | 1℃ |
-4℉-600℉ | ±(1.2%+6d) | 1℉ |
601℉-1832℉ | ±(1.9%+6d) | 1℉ |
- Overload protection: 250V DC or AC (rms)
Technical indicators
Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
3.2.1 True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS
measurement method than the traditional average response method
error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine
wave signal, but if it is on the AC function, the instrument may
display 1 to 50 if the measured signal is not input (shorted at the
AC voltage range and the input terminal) Word between a reading.
These deviations are normal. Within the specified measuring range,
they do not affect the accuracy of the multimeter to measure
alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain
level for measurement. Therefore, the AC voltage and current range
is specified between 2% and 100% of full scale.
FAQ:
What is your MOQ?Lead time?
We donot have MOQ on all products, 1 PC is also OK. Nearly all
products are in stock for fast shippment, usually 3 working days,
but in alibaba we write 10 days since sometimes the logistic
information will be delayed(some items we send by our courier not
by alibaba directly so logistics data is slow to update).
Do you accept OEM/ODM service?
Both OEM and ODM are highly welcomed as long as you meet our MOQ
and we prefer orders such as OEM and ODM since quantity is large
and clients are steady.
What is your after-sale service and warranty?
Our warranty is one year and we can repair free for you within
warranty as long as the problem is not made personally. If personal
problems and out of warranty then buyer have to pay the shipping
fee and repair fee if needed.For small items we can send free
replacement in next order.
What is your payment term and business term?
You can pay us by paypal,western union, Sigue,Veem,bank
transfer,Escrow, any method is OK.For sample we usually send by
express such as DHL,EMS,UPS,Fedex,Aramex etc,sea shippment and
truck shippment all OK.For business term, FOB,EXW,DAP,CIF all
accepted.
How can we trust you?And how we find you if you donot send the
product?
We are located in Longhua District,Shenzhen, you can ask any
Chinese friend to visit us. After your order is placed, if we donot
ship on time, you can complain to alibaba . If you pay by escrow or
paypal, it is even safer. You can find us by whatsapp/wechat/Email
any time(24 hours* 7 days), if we donto reply on time we may sleep
during night,we will reply you asap.
How to place an order?
You can choose the model and quantity you want, then we check the
shipping fee and send you the Proforma invoice to pay. Payment
online by escrow is welclomed, others also OK. After you pay us we
will send directly to your address, then you pay get phones from
local express to pay tax if needed, after that they deliver to you.
If online payment by escrow pls donot forget to give us feedback if
you are satisfied with the product and our service.
![]() |