Sign In | Join Free | My himfr.com
Home > Digital Smart Multimeter >

LCD Digital Multimeter AC DC Voltage Diode Frequency Multimeter Voltage Tester Test Current

SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
Contact Now
    Buy cheap LCD Digital Multimeter AC DC Voltage Diode Frequency Multimeter Voltage Tester Test Current from wholesalers
     
    Buy cheap LCD Digital Multimeter AC DC Voltage Diode Frequency Multimeter Voltage Tester Test Current from wholesalers
    • Buy cheap LCD Digital Multimeter AC DC Voltage Diode Frequency Multimeter Voltage Tester Test Current from wholesalers

    LCD Digital Multimeter AC DC Voltage Diode Frequency Multimeter Voltage Tester Test Current

    Ask Lasest Price
    Brand Name : CHX
    Model Number : CHX-DM035
    Certification : CE, RoHS
    Price : Negotiation
    Payment Terms : T/T, Western Union,Paypal,L/C
    Supply Ability : 50000pcs/month
    Delivery Time : 5-35days
    • Product Details
    • Company Profile

    LCD Digital Multimeter AC DC Voltage Diode Frequency Multimeter Voltage Tester Test Current


    LCD Digital multimeter DC AC Voltage Diode Freguence multimeter Volt Tester Test Current


    Follow the steps below to replace the battery


    1) Turn off the instrument power supply.

    2) Remove all test leads from the input socket.

    3) Unscrew the captive screws of the battery cover and remove it.

    4) Remove the battery cover.

    5) Replace the new 6F22 9V battery

    6) Install the battery cover as it is, tighten the screws.


    Function selection


    1) In the voltage range, press "FUNC" key, will be in the AC voltage, DC voltage cycle between the switch.
    2) In the resistor, diode, buzzer file, press the "SEL" button, will be in the resistance, on-off detection, diode three file cycle switch.
    3) In the frequency, duty cycle file, press the "FUNC" key, will be in the frequency, duty cycle between the switch.
    4) In the temperature range, press the "FUNC" key, will be in degrees Celsius and Fahrenheit cycle switch.
    5) In the current file, press "FUNC" key, will be in the AC current, DC current cycle between the switch


    backlight and lighting


    1) During the measurement, if the ambient light is too dark, the reading is difficult, press the " " button for more than 2 seconds, turn on the backlight and the lights, and turn off automatically after about 15 seconds.
    2) During this period, if the " " button for more than 2 seconds will manually turn off the backlight and lighting.
    Backlight and lighting of the luminous body for the LED, the working current is large, although the instrument has a timer circuit (timing time of about 15 seconds), but often use the backlight and lighting will shorten the battery life, so unnecessary Of the circumstances, should be used as little as possible backlight.


    Technical indicators

    Ambient temperature: 23 ± 5 ℃

    Relative humidity: <75%
    3.2.1 True rms zero input
    3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
    3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
    3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.


    3.2.2 DC voltage

    RangeResolutionAccuracy
    6V0.001V±(0.5% of reading + 5 words)
    60V0.01V
    600V0.1V±(0.8% of reading + 5 words)

    - Input impedance: 10MΩ
    - Maximum input voltage: 600V DC or 600V AC (rms)
    Note:
    In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
    This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.


    3.2.3 AC voltage

    RangeResolutionAccuracy
    6V0.001V±(0.8% of reading + 3words)
    60V0.01V
    600V0.1V±(1.0% of reading + 10words)

    - Input impedance: 10MΩ

    - Maximum input voltage: 600V AC (RMS) or 600V DC

    - Frequency range: 40 ~ 1000Hz True RMS

    Note:
    In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
    This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.



    3.2.4 Alternating current

    RangeResolutionAccuracy
    600.0uA0.1uA±(1.5% of reading +10words)
    6000uA1uA
    60.00mA0.01mA
    600.0mA0.1mA
    6A0.001A±(2.5% of reading +10words)
    10A0.01A

    - Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
    10A range without insurance
    - Maximum input current: mA: 600mA DC or AC rms;
    10A: 10A DC or AC rms;
    When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
    - Frequency response: 40Hz ~ 1000Hz True RMS.

    3.2.5 DC

    RangeResolutionAccuracy
    600.0uA0.1uA±(1.0% of reading +5words)
    6000uA1uA
    60.00mA0.01mA
    600.0mA0.1mA
    6A0.001A±(2.0% of reading +10words)
    10A0.01A

    - Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
    10A range without insurance
    - Maximum input current: mA: 600mA DC or AC rms;
    10A: 10A DC or AC rms;
    When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.


    3.2.6 Frequency

    RangeResolutionAccuracy
    9.999Hz0.001Hz±(1.0% of reading +3words)
    99.99Hz0.01Hz
    999.9Hz0.1Hz
    9.999kHz0.001kHz
    99.99KHZ0.01kHZ
    999.9KHZ0.1KHZ
    9.999MHZ0.001MHZ

    - Overload protection: 250V DC or AC (rms)
    - Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)


    3.2.7 Duty cycle

    RangeResolutionAccuracy
    0.1 – 99.9%0.1%± 3.0%

    - Frequency response: 10 ~ 10MHz

    - Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)

    - Maximum input voltage: 250V AC (rms)

    Resistance

    RangeResolutionAccuracy
    600W0.1W±(0.8% of reading +3words)
    6kW0.001kW
    60kW0.01kW
    600kW0.1kW
    6MW0.001MW±(1.2% of reading +3words)
    60MW0.01MW

    - Open circuit voltage: approx. 1.0V
    - Overload protection: 250V DC or AC (rms)

    Transistor test


    RangeDescriptionTest Conditions
    hFEThe display reads the approximate value of hFE(0~1000)Base current of about 10uA; Vce about 2.8V

    Capacitance


    RangeResolutionAccuracy
    9.999nF0.001nF±(4.0% of reading +3words)
    99.99nF0.01nF
    999.9nF0.1nF
    9.999mF0.001mF
    99.99mF0.01mF
    999.9mF0.1mF
    9.999mF0.001mF±(5.0% of reading +3words)
    99.99mF0.01mFNot calibrated

    - Overload protection: 250V DC or AC (rms)


    Temperature test


    RangeAccuracyResolution
    -20℃-300℃±(1.0%+4d)1℃
    301℃-1000℃±(1.9%+5d)1℃
    -4℉-600℉±(1.2%+6d)1℉
    601℉-1832℉±(1.9%+6d)1℉

    - Overload protection: 250V DC or AC (rms)


    Quality LCD Digital Multimeter AC DC Voltage Diode Frequency Multimeter Voltage Tester Test Current for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)